Review Details: COMMERCIAL - TI
Permit Number - T19CM08397
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/26/2019 | PAUL CAMARENA | ZONING | REVIEW | Approved | |
| 11/29/2019 | RMCCOY1 | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Illustrate the Exit Access Travel Distances on plan sheet G101. IBC 107.2.1. |
| 12/09/2019 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 12/11/2019 | RMCCOY1 | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 12/19/2019 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Verify that the distance from the hot water source to the hot water termination for the public lavatories complies with the requirements of Section C404.5, IECC 2018. 2. Verify that the metering faucets for the public lavatories will operate for at least 10-seconds for accessibility. Reference: Section 606.4, ICC/ANSI A117.1-09. |
| 12/19/2019 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 12/19/2019 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. The City of Tucson has adopted the 2018 IMC as the approved method for calculating ventilation requirements, not ASHRAE 62.1. Verify the ventilation requirements for HP-7 and HP-8 using the occupant density given in Table 403.3.1.1, IMC 2018 (You may want to revise the room description from aerobics to weight room). 2. Revise the sequence of operation for the restroom exhaust fan so that all of the air supplied to the restrooms will be exhausted (i.e. all of the air supplied to each restroom is to be exhausted during the hours of operation even if the lights are off). Reference: Section 403.2.1 (4), IMC 2018. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/20/2019 | SBORZAK1 | OUT TO CUSTOMER | Completed |