Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: PLANS OK TO SUBMIT - RES
Permit Number - T19CM08361
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/09/2020 | ARUIZ1 | ENGINEERING | REVIEW | Needs Review | |
| 09/09/2020 | ARUIZ1 | BUILDING-RESIDENTIAL | REVIEW | Needs Review | |
| 11/12/2019 | SAMUEL ROGERS | ZONING | REVIEW | Needs Review | ZONING REVIEW TRANSMITTAL FROM: Paul Camarena Planner PROJECT: T19CM08361- T19CM08358 2034 E 2nd St Unit 1 and Unit 2 New SFR TRANSMITTAL: November 12, 2019 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2. A). For the east portion for the front residence the required setback 7'4" the proposed setback is 3'6". For the west portion for the front residence the required setback is required setback is 8' the proposed setback is 4'2". For the back residence the required setback is 6' the proposed setback is 1' The maximum height of a wall or fence within a perimeter yard shall be six (6) feet (UDC Section 6.6.2.I). The maximum height of a retaining wall is ten (10) feet from design grade and no higher than six (6) feet measured from the top of the retaining portion of the wall (UDC Section 6.6.2.I.2). For the west side site wall the proposed height is 7'9" the required height is 6' |
| 11/12/2019 | SROGERS2 | NPPO | REVIEW | Passed | |
| 11/12/2019 | SAMUEL ROGERS | ZONING | REVIEW | Needs Review | ZONING REVIEW TRANSMITTAL FROM: Paul Camarena Planner PROJECT: T19CM08361- T19CM08358 2034 E 2nd St Unit 1 and Unit 2 New SFR TRANSMITTAL: November 13, 2019 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2. A). For the east portion for the front residence the required setback 7'4" the proposed setback is 3'6". For the west portion for the front residence the required setback is required setback is 8' the proposed setback is 4'2". For the back residence the required setback is 6' the proposed setback is 1' For the carport required front setback is 20' the proposed setback is 17'. The required side setback for the carport is 6'6" the proposed is 3' with 2' of overhang. The maximum height of a wall or fence within a perimeter yard shall be six (6) feet (UDC Section 6.6.2.I). The maximum height of a retaining wall is ten (10) feet from design grade and no higher than six (6) feet measured from the top of the retaining portion of the wall (UDC Section 6.6.2.I.2). For the west side site wall the proposed height is 7'9" the required height is 6' |