| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/05/2019 | SBORZAK1 | ZONING | REVIEW | Completed | Show the location of the utility AC disconnect, solar meter on the site plan. |
| 11/05/2019 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T19CM08182 PLAN REVIEW COMMENTS Plan review for the above referenced structure is completed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code, 2018 International Fire Code, 2017 National Electrical Code and Arizona Revised Statutes. All features were checked to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: Make all corrections and revisions on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections are complete, and have been coordinated on all applicable detail sheets. GENERAL NOTES: " Limit all code references to those recognized by the City of Tucson. The 2017 NEC is listed at the Planning & Development Services web site. " Provide manufacturer specification sheets for collector panels, inverter and mounting hardware. DIAGRAMS / CALCULATIONS 1. Show a plan of sufficient lag-bolt connections for maintaining the up-lift calculation and with standoff placement for preventing point loads over 45 pounds, R301.1. Show the lag bolts size and spacing. NOTES / SPECIFICATIONS 1. Provide the exact wording and location for the system labels required by NEC 690.13. 2. Provide the exact wording and location for the Power Source "Imp, Vmp, Vmax, Isc, Wmax" marking required by NEC 690.51. 3. Provide the exact wording and location for the "Rapid Shutdown Switch" marking required by NEC 690.56(C) 4. Show the back feed breaker at the opposite end on the panelboard from the main feeder location and label "Do Not Relocate", NEC 705.12 (B)(2)(3). If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 11/05/2019 | SBORZAK1 | ENGINEERING | REVIEW | Completed |