Review Date Reviewer's Name Type of Review Description Status Comments
01/16/2020 DAVID RIVERA ZONING REVIEW Reqs Change FROM: Loran Shamis
PDSD Zoning Review Section

PROJECT: T19CM07736
New studio addition (Minor Subdivision Permit S19-076)
6008 E 30st ST - R-1

TRANSMITTAL DATE: 01/16/20

DUE DATE: 01/29/20

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


01. Provide building plan for building on Parcel 1 (existing residence).

02. Revise Legal Description to match the legal description for the new parcel as recorded by the minor subdivision.

03. Provide building plan for the entire building on Parcel 2 (existing workshop and new studio residence).

04. Provide lot coverage calculations for Parcel 1.

05. Provide vehicular access information to each parcel (will an ingress/egress easement be provided for vehicular access from parcel 2 to parcel 1 (parcel3)? If easement is proposed, draw easement proposal from 30th street to proposed location)

06. What is proposed for parcel 3?

07. Provide square footage for lot, existing dwellings, additions to existing dwellings.

08. Provide setbacks for Parcel 2 to the proposed property line for the proposed building to the north property lot line and from the existing building to the north proposed property line.

09. Provide setbacks for Parcel 1 for the existing building to the proposed lot lines to the east and to the proposed south lot line.

10. Show the locations of all utilities to parcel 1.

11. Annotate the zoning classifications adjacent to the development site.

12. Plan reviewed under the assumption the lot split permit is approved.

13. Building plans will not be approved until the minor subdivision is approved.


If you have any questions about this transmittal, Contact Loran Shamis by email Loran.shamis@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans
02/03/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T19CM07736
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

FLOOR PLANS:

1. Show the door from a garage to dwelling with a 20-minute fire rating (or 1-3/8" solid core) with self-closing and self-latching provision, R302.5.1.

PLUMBING PLANS:

1. Show consistent room usage. A second bathroom is not shown on other sheets, R106.1.1.

MECHANICAL PLANS:

1. Provide demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. Systems shall be sized in accordance with Manual S based on building loads calculated in accordance with Manual J and duct systems sized in accordance with Manual D. Notate if the mechanical system calculations may be provided by deferred submittal. The deferred calculations must be approved through revision process prior to mechanical inspections.

ELECTRICAL PLANS:

1. Show or notate the requirement for a carbon monoxide detector outside of bedroom doors, when the dwelling includes an attached garage or gas appliance, R315.
2. Peninsular counter tops require at least one receptacle outlet within 12" below the countertop surface, E3901.4.2 and E3901.4.3.
3. Specify high-efficacy lamps for at least 90% of all lighting fixtures, N1104.1.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans.

If you have any questions please contact: