Permit Number: T19CM07377
Parcel: 107020090

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T19CM07377
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/16/2020 RMCCOY1 BUILDING-COMMERCIAL REVIEW Approved
03/16/2020 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change The COMcheck Envelope Compliance form on sheet G0.1 describes a wood-framed building with a wood-framed attic roof. Coordinate the COMcheck form with the description of the building that is being built. [Second comment: The wall insulation described in the COMcheck form does not agree with the general note on sheet A5.1.] [Initial comment: Provide energy code compliance calculations for the building envelope; use the climate zone for Tucson. Provide sufficient detail on the drawings to evaluate the energy compliance of the building envelope (e.g. building and wall sections, building elevations, etc.). The information shall, as a minimum, include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation and the SHGC for the fenestration. Reference: Sections C101.5, C103.2, C303, and C401.2, International Energy Conservation Code 2018.]
03/16/2020 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
03/27/2020 LOREN MAKUS ENGINEERING REVIEW Approved
04/07/2020 ARUIZ1 ZONING REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
04/07/2020 ARUIZ1 APPROVAL SHELF Completed
04/07/2020 ARUIZ1 OUT TO CUSTOMER Completed
04/07/2020 ARUIZ1 REJECT SHELF Completed