10/03/2019 PAUL CAMARENA ZONING REVIEW Needs Review ZONING REVIEW TRANSMITTAL

FROM: Paul Camarena
Planner

PROJECT:
T19CM07247, T19BU00501
926 M 2nd Ave
New SFR

TRANSMITTAL: October 3, 2019
COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8).

This site is located in the HR-3 zone (UDC 4.7.12). Multi-family residential is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7.B.6.

The minimum setback is the greater of ten (10) feet, or three-fourth (3/4) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The minimum setback to a side street property line is ten (10) feet (UDC Section 6.4.5.C.1.b).

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a).


Historic Review Required for New Construction and Demo.