Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T19CM07073
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/28/2019 | IMONSHI1 | ZONING | REVIEW | Reqs Change | FROM: Iman Monshizadeh PDSD Zoning Review Section PROJECT: T19CM07073 - New addition to SFR - (SF - Residential) Building Plan Review (2nd Review) Bedroom and Porch Addition 226 W CALLE NUEVA VIDA / R-1 Zoning TRANSMITTAL DATE: October 28th, 2019 DUE DATE: November 8th, 2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. COMMENT: Revise lot coverage percentage calculations of the addition of the new bedroom and porch. Lot coverage calculations should include the full lot. 2. COMMENT: Provide a note stating the height of the bedroom and porch additions. If you have any questions about this transmittal, Contact Iman Monshizadeh at (520) 837-4082 or by email Iman.Monshizadeh@tucsonaz.gov or contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov |
| 11/01/2019 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T19CM07073 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. SECTIONS - DETAILS: 1. Clarify the roof framing members shown on the Wall Section, R301.1. Sheet S-06 shows 2x6 rafters and the Wall Section shows a 2x12 fascia. 2. Extend the sheathing to the finish floor level or below. Show the weep screed with a minimum clearance 4" above grade or 2" above paved areas, R703.7.2.1. Also, remove the 24' notation. Update the Wall Section on sheet S-05. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/04/2019 | SBORZAK1 | OUT TO CUSTOMER | Completed |
| 11/04/2019 | SBORZAK1 | REJECT SHELF | Completed |