Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T19CM06253
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/10/2019 | MARTIN BROWN | FIRE | REVIEW | Approved | |
09/20/2019 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
10/02/2019 | ROBERT SHERRY | WATER | REVIEW | Completed | |
10/02/2019 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comments. Also provide a written response. 1. Please provide a complete panel schedule for panel 'LV5C'. Ref; 2018 IBC sec 107.2.1, 2017 NEC. City of Tucson Commercial Plan Submittal requirements. |
10/03/2019 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Section R4-30-304 of the Rules of the Arizona State Board of Technical Registration, states that the registrant's seal shall have both a signature of the registrant and the date the document was sealed. 2. Terminate condensate drains in accordance with Section 307.2.1, IMC 2018, as amended by the City of Tucson. Waste receptors ("open site drain") require ready access. Reference: Section 802.4, IPC 2018. 3. All exhaust fans shall discharge outdoors. Reference: Section 501.3, IMC 2018. |
10/04/2019 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Section R4-30-304 of the Rules of the Arizona State Board of Technical Registration, states that the registrant's seal shall have both a signature of the registrant and the date the document was sealed. 2. Indirect waste receptors shall not be installed in concealed spaces. Provide ready access to the waste receptor. Reference: Section 802.4, IPC 2018 3. Show that the floor drains used as indirect receptors for condensate (details 1/P0.02 and 5/P0.02) are capable of accepting the maximum discharge and are designed to prevent splashing or flooding. Reference: Section 802.4.1, IPC 2018. 4. Verify that all of the vents rise vertically to at least 6" above the flood rims of the fixtures they protect prior to running horizontally. Reference: Section 905.4, IPC 2018. |