Permit Number: T19CM06010
Parcel: 123071360

Address:
1218 N OLSEN AV

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T19CM06010
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/21/2019 PCAMARE1 NPPO REVIEW Passed
08/21/2019 PCAMARE1 ENGINEERING REVIEW Passed
09/27/2019 ARUIZ1 BUILDING-RESIDENTIAL REVIEW Needs Review
11/07/2019 PAUL CAMARENA ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: Paul Camarena
Planner

PROJECT:
T19CM06010
1218 N Olsen Av
Addition Bike garage

TRANSMITTAL: August 21, 2019
COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The height of the addition is 11-4" requiring a 7-5" setback. The proposed setback for the south property line is 3' 2".
The shed has a required setback of 6', the proposed setback is 3.5' on the south and 2' on the East.

A DDO is required.