Permit Number: T19CM05299
Parcel: 11004345K

Address:
3315 N SWAN RD

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T19CM05299
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/29/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. For accessibility, automatic faucets for public lavatories must operate for at least 10-seconds. At 0.5 GPM, the maximum cycle time is 30-seconds. Reference: Section 606.4, ICC/ANSI A117.1-09.
2. Verify that approved devices conforming to ASSE 1070 provide the tempered water for the public restroom lavatories. Reference: Sections 416.5 and 607.1.2, IPC 2018.
3. Verify that the distance from the hot water source to the hot water termination for the public lavatories complies with the requirements of Section C404.5, IECC 2018.
07/29/2019 MARTIN BROWN FIRE REVIEW Approved
07/30/2019 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change Keyed Note M1 on sheet M1.1 calls for the contractor to record the supply air CFM for balancing the dining area HVAC system. Calculate the required outside air for the dining area so the contractor can correctly balance the system. Reference: Section 403.3.1, IMC 2018.
07/30/2019 ROBERT SHERRY WATER REVIEW Completed
08/15/2019 SAMUEL ROGERS ZONING REVIEW Approved
08/20/2019 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
08/22/2019 JOHN VAN WINKLE ENGINEERING REVIEW Approved
09/05/2019 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved