| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/17/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | REMOVE THE STOVE CIRCUIT FROM THE PANEL SCHEDULE. NOT PERMITTED WITHOUT ZONING APPROVAL FOR A DWELLING WITH NEW ADDRESS. CHANGE CIRCUIT #11 TO 20 AMP FOR THE LAUNDRY. SHOW CIRCUIT #7 AND STORAGE ROOM AS ARC-FAULT. |
| 06/02/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | FROM: Zoning Review PROJECT: T19CM05241 2827 N Cherry Ave Convert Garage to Sleeping Quarters TRANSMITTAL: June 2, 2021 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall, see Unified Development Code (UDC) Article 6.4.5.B & Figure 6.4.5-A. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). 1. Based on a wall height of 9’-4” the required perimeter yard setback from the proposed sleeping quarters to the north and west property line is 6’-3”, proposed to the north is 3’-0” and to the west is 1’-6”. At a minimum a neighbor setback waiver is required to reduce the perimeter yard setbacks. To accomplish the waive the following text shall be provided on the site plan for both the neighbor to the north and west and then signed and dated by the owner of the adjacent property. My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ If you are unable to secure the required owner signatures a Design Development Option (DDO) will need to be submitted and approved, DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov. |