Permit Number - T19CM05078
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/29/2020 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 08/03/2020 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 08/03/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | Comment not addressed. [Third comment: An L-1 lavatory with a non-metering faucet is still shown in public restrooms (e.g. rooms 1140, 1141, 1185B, 1483, 1514B, 1591, 2214, and 2421)] [Second comment: Lavatory model L-1 installed in public restrooms requires a metering faucet. Provide a statement requiring that the time out for the automatic faucets be set to 30-seconds.] [Initial comment: Provide automatic faucets for lavatories located in public restrooms (including staff restrooms). Verify that the automatic faucets will operate for a minimum time of 10-seconds but have an automatic time out to limit the amount of water dispensed to 0.25 gallons per cycle. Reference: Section 419.6, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09.] |
| 08/03/2020 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved |