Permit Review Detail
Review Status: Active
Review Details: PLANS OK TO SUBMIT - RES
Permit Number - T19CM04909
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/10/2019 | SMEGGIS1 | ZONING | REVIEW | Reqs Change | FROM: Sarah Meggison, AICP Planner PROJECT: T19CM04908 and T19CM04909 674 S. Main Avenue Two New SFRs - Proposed FLD TRANSMITTAL: July 10, 2019 COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8). These comments are based on a proposed future FLD application. Additional zoning review may be required once FLD/Historic/BOA have reviewed. This site is located in the HO-3 zone (UDC 4.7.15). Applicant is proposing 0' setback based on proposed new property lines per future FLD. Required setbacks based on O-3 zone are 10' or ¾(H) on interior lot lines. Additionally, Main Avenue is an MS&R and proposal is not meeting required 21' setback from edge of nearest travel lane, the proposed setback is 15'-8" on Main Avenue. Historic review is required. Applicant is proposing no on-site maneuverability and does not meet MS&R setbacks, variances are required. |
| 07/10/2019 | SMEGGIS1 | NPPO | REVIEW | Passed | |
| 07/10/2019 | ANY | ENGINEERING | REVIEW | Active | |
| 07/10/2019 | ANY | BUILDING-RESIDENTIAL | REVIEW | Active |