Permit Number: T19CM04834
Parcel: 115040460

Review Status: Active

Review Details: RESIDENTIAL - BLDG/WWM

Permit Number - T19CM04834
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
08/05/2019 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T19CM04834
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

SITE PLAN:

1. Indicate the location of buildings, fences, utility meters and electric lines to the proposed building, R106.1.1.

SECTIONS - DETAILS:

1. Provide the height of the proposed fence, R106.1.1. A design and inspection is required for a fence over 7 feet high.

ELECTRICAL PLANS:

1. Show a feeder location extending to the accessory (detached) building, NEC 225.30.
2. Garage Branch Circuit: a separate (dedicated) GFCI 20-amp branch circuit required for receptacles in an attached garage and detached garages with service, E3703.5. Upgrade a 15-amp circuit.

OUTDOOR LIGHTING CODE

1. Show the proposed fixture as full cut-off FCO style, or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
08/15/2019 PAUL CAMARENA ZONING REVIEW Reqs Change FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: T19CM04834
Residential Building Plan Review (2nd Review)
420 E Drachman St. NR-1 - Feldmans


TRANSMITTAL DATE: August 15, 2019

DUE DATE: August 26, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

*** The comment by Steve Shields is still applicable. Zoning cannot approve until the NPZ application has been completed and approved or a DDO application has been completed and approved.


COMMENTS: the following comments are relative to an application for NPZ Review (UDC 5.10.3).

This site is located in the NR-1 zone (UDC 5.10.3). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

Prior to zoning approval an NPZ review and approval is required. Owner is proposing to construct a 20' x 14' detached garage with solar to the rear of the property. The property fronts on two local streets Drachman and Hoff. The structure location is proposed to be 3' from the property line along the side street, required side street perimeter yard setback is 10'-0". Applicant is seeking relief from required setback through NPZ review. If not DDO is required.


If you have any questions about this transmittal, Contact Paul Camarena any time during the week at (520) 791-5550 or by email Paul.Camarena@Tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans

Final Status

Task End Date Reviewer's Name Type of Review Description
07/29/2019 ANY REJECT SHELF RECEIVED