Permit Number: T19CM04663
Parcel: 11707074A

Address:
524 S HERBERT AV

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T19CM04663
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/08/2020 ARUIZ1 BUILDING-RESIDENTIAL REVIEW Needs Review
06/28/2019 AHINES2 NPPO REVIEW Passed
06/28/2019 AHINES2 ENGINEERING REVIEW Passed
11/01/2019 ALEXANDRA HINES ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: Samuel - Planner
PROJECT: T19CM04663
524 S Herbert Av
Remodel SFR: Add bedroom, bathroom, and rear porch

TRANSMITTAL: 6/28/19
COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8).

This site is located in the HR-3 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The proposed setback is zero (0) feet to north and south side property lines. The required setback is (11'6") based on 2/3(17'3").

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a).

The existing setback is five (5) feet to front property line. Provide records that setback was created prior to UDC.

HPZ approval is required prior to zoning approval on building permit.