Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T19CM04563
Parcel: 11918086A

Address:
3736 S 16TH AV

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T19CM04563
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/08/2019 MARTIN BROWN FIRE REVIEW Approved
07/15/2019 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
07/15/2019 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change Provide design documents for any proposed mechanical modifications. Reference: Section 107.1, IBC 2018.
07/15/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Provide design documents for any proposed plumbing modifications. Reference: Section 107.1, IBC 2018.
07/15/2019 ROBERT SHERRY WATER REVIEW Completed
07/15/2019 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Sheet A000 (Code Analysis); Sheet A-101 (Exiting/Occupancy Plan): The Code Analysis indicates 19 total occupants, while the exit doors indicate 14 total occupants (7 at each exit). Please verify.
2. Sheet A-101; Exiting/Occupancy Plan: Per the IBC Section 1017.3, the exit access travel distance shall be measured along the unobstructed path of horizontal and vertical egress travel. Part of the exit access travel distance in the Open Office Area is measured along a diagonal line. Please revise.
3. Sheet A-101; Exiting/Occupancy Plan: Per the IBC Table 2902.1, two restrooms would be required for the 19 occupants in a B Occupancy Classification, along with a drinking fountain and a service sink. If this tenant space had a B Occupancy Classification for the previous use, the existing plumbing fixtures would be acceptable. A change in the Occupancy Classification would require a new analysis for all required plumbing fixtures. Please verify.
4. Sheet A-201; Elevation 6: It appears the Sections 4/A-201 and 7/A-201 should be reversed. Please verify.
5. Sheet A-201; Detail 8: Please indicate a reference to this detail on the plans, notes, sections, details, etc.
6. General: Please provide written responses to all review comments.

Reviewed by Eric Newcomb
Contact at 520-837-4911 or Eric.Newcomb@tucsonaz.gov
07/26/2019 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please address the following electrical plan review comments. Also provide a written response.
1. Ref; Plan Sheet A-201. In reference to Keyed note #1 for the lighting. Please designate a branch circuit and panel for the new lighting. Also provide a luminaire schedule and compliance with the 2018 IECC.
Ref; 2018 IBC sec 107.2.1, 2017 NEC, 2018 IECC.
07/30/2019 DAVID RIVERA ZONING REVIEW Approved
08/01/2019 JOHN VAN WINKLE ENGINEERING REVIEW Passed