Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/08/2019 | MARTIN BROWN | FIRE | REVIEW | Approved | |
07/15/2019 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
07/15/2019 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | Provide design documents for any proposed mechanical modifications. Reference: Section 107.1, IBC 2018. |
07/15/2019 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Provide design documents for any proposed plumbing modifications. Reference: Section 107.1, IBC 2018. |
07/15/2019 | ROBERT SHERRY | WATER | REVIEW | Completed | |
07/15/2019 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet A000 (Code Analysis); Sheet A-101 (Exiting/Occupancy Plan): The Code Analysis indicates 19 total occupants, while the exit doors indicate 14 total occupants (7 at each exit). Please verify. 2. Sheet A-101; Exiting/Occupancy Plan: Per the IBC Section 1017.3, the exit access travel distance shall be measured along the unobstructed path of horizontal and vertical egress travel. Part of the exit access travel distance in the Open Office Area is measured along a diagonal line. Please revise. 3. Sheet A-101; Exiting/Occupancy Plan: Per the IBC Table 2902.1, two restrooms would be required for the 19 occupants in a B Occupancy Classification, along with a drinking fountain and a service sink. If this tenant space had a B Occupancy Classification for the previous use, the existing plumbing fixtures would be acceptable. A change in the Occupancy Classification would require a new analysis for all required plumbing fixtures. Please verify. 4. Sheet A-201; Elevation 6: It appears the Sections 4/A-201 and 7/A-201 should be reversed. Please verify. 5. Sheet A-201; Detail 8: Please indicate a reference to this detail on the plans, notes, sections, details, etc. 6. General: Please provide written responses to all review comments. Reviewed by Eric Newcomb Contact at 520-837-4911 or Eric.Newcomb@tucsonaz.gov |
07/26/2019 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comments. Also provide a written response. 1. Ref; Plan Sheet A-201. In reference to Keyed note #1 for the lighting. Please designate a branch circuit and panel for the new lighting. Also provide a luminaire schedule and compliance with the 2018 IECC. Ref; 2018 IBC sec 107.2.1, 2017 NEC, 2018 IECC. |
07/30/2019 | DAVID RIVERA | ZONING | REVIEW | Approved | |
08/01/2019 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Passed |