Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T19CM04278
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/21/2019 | DMCCART1 | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T19CM04278 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL COMMENTS: 1. Whole House mechanical ventilation Provide (an HVAC system with) whole-house mechanical ventilation with continuous or a minimum controlled intermittent airflow rate, R303.4 & M1505. Show a source of outside supply air or continuous exhaust fan function. 2. Update all code references to 2018 IRC, all pages . 3. Gas pipe undersized 1 ΒΌ inch 350,000 only good for 125 feet. As drawn 127 feet. 4. Provide manufacturer's calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or notate the requirement for deferred submittal, R106.1. Deferred submittal. 5. Provide Manual J-Load calculations for HVAC. Dan McCarthy Daniel.mccarthy@tucsonaz.gov |
| 06/21/2019 | DMCCART1 | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLEASE PROVIDE STRUCTURAL DESIGN AND CALCULATIONS FOR FOUNDATION RETAINING WALL. Include soils evaluation as per 401.4 and 401.4.1. And perimeter drain as per IRC 405, Foundation water-Damproofing as per IRC 406, and backfill as per 404.1.7 and 406.3.3. |
| 07/02/2019 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 07/09/2019 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | FROM: David Rivera PDSD Zoning Review Section PROJECT: T19CM04278 Related to DP19-0143 New Single Family Residence - Building Plan (Project Type) (1st Review) 885 S. Tohono Ridge Place - R-1 Zoning RCP (Star Pass Master Area) TRANSMITTAL DATE: July 9, 2019 DUE DATE: July 10, 2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 01. COMMENT: Zoning has reviewed the Building Plans for the new Single Family Residence development for compliance as it pertains to the zoning review purview; Building setbacks, Building Height, Lot coverage, etc. 02. COMMENT: While the proposal is in compliance with the zoning requirements, the building plans cannot be approved until PDSD Residential Building Plans reviewer has approved the plans. 03. COMMENT: Once the building plans have been approved by the PDSD Residential Building Plans reviewer, zoning can approve the plans as well. 04. COMMENT: Zoning is willing to do an over the counter digital review and approval once the PDSD Residential Building Plans reviewer has approved the plans. If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans |
| 07/09/2019 | DAVID RIVERA | NPPO | REVIEW | Approved | |
| 07/15/2019 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | T19CM04278 1) Once the development plan has been approved, Engineering can review and approve the building plans John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |