Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T19CM04210
Parcel: 136334870

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T19CM04210
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/17/2019 ANDREW CONNOR ZONING REVIEW Approved FROM: Andrew Connor
Planner

PROJECT:
T19CM04210
3022 S Eastview Ave.
Attached carport.

TRANSMITTAL: June 17, 2019

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The DDO process may only be used to reduce the driveway length to a carport, and not to a garage (UDC Section 3.11.1.B.4). In a developing area, the minimum driveway length to the edge of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b).

The applicant is proposing an attached carport with a maximum height of 9' 6" to the north with a setback of 2' and a front yard setback of 17' 6" to the East.
10/17/2019 PCAMARE1 ENGINEERING REVIEW Passed
10/17/2019 PCAMARE1 NPPO REVIEW Passed
10/17/2019 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed