Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Permit Number - T19CM03733
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/24/2019 | ALEXANDRA HINES | ZONING | REVIEW | Reqs Change | FROM: Alexandra Hines, AICP - Lead Planner PROJECT: T19CM03733 5441 E Burns St Add Carport - Attached TRANSMITTAL: May 24, 2019 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. Within established areas, the minimum required front street perimeter yard is 20 feet or one and one-half the height of the proposed wall (H), measured from the street property line, whichever is greater, up to a maximum of 90 feet. (UDC 6.4.5.C.1.a). Based on a carport wall height of 9', the required front street perimeter yard setback is 20', proposed is 10'. Eighteen feet (the length of a standard parking space) must be provided in front of the carport or garage and measured so that the full 18-foot parking space is available for parking on-site (UDC 6.4.5.C.2.b). The required driveway length is 18', proposed is 10'. DDO approval required prior to zoning approval. |
| 05/24/2019 | AHINES2 | ENGINEERING | REVIEW | Passed | |
| 05/24/2019 | AHINES2 | NPPO | REVIEW | Passed | |
| 07/10/2019 | PMARTIN1 | BUILDING-RESIDENTIAL | REVIEW | Needs Review |