Permit Number: T19CM03546
Parcel: 123031090

Address:
2732 E LEE ST

Review Status: Completed

Review Details: REVISION - - 2ND

Permit Number - T19CM03546
Review Name: REVISION - - 2ND
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/10/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T19CM03546 R2
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

FLOOR PLANS:

1. Identify the room opening into the bathroom addition on the plans. Show a sleeping room with R310 compliant egress.

ELECTRICAL PLANS:

1. Show a single feeder or branch circuit to the accessory (detached) building, NEC 225.30. Consider a feeder from the service panel to a sub panel located at the garage.

OUTDOOR LIGHTING CODE

1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
03/23/2021 SSHIELD1 ENGINEERING REVIEW Passed
03/23/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM03546
2732 E Lee St
Expand 122 S.F. Addition & add Detached Garage

TRANSMITTAL DATE: March 23, 2021

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5-.9.

1. Per UDC Article 6.4.5.C.B the required side street perimeter yard setback is 10’-0”. Proposed perimeter yard setback from the proposed detached garage to the street perimeter property line along Treat Ave is 3’-7”.

2. Until a new side street perimeter yard setback is provided from the previous 122 S.F. addition which has be expanded, required Zoning comments cannot be provided for the required Design Development Option (DDO) cannot be provided.

A Design Development Option (DDO) will need to be submitted and approved for both comments above. DDO requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. Submit the DDO at:
https://www.tucsonaz.gov/pdsd-filedrop.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
03/24/2021 LBOWERS1 OUT TO CUSTOMER Completed