Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T19CM03374
Parcel: 141114100

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T19CM03374
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/30/2020 ROBERT SHERRY WATER REVIEW Passed
05/01/2020 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. Correct the Mechanical Compliance Certificate (COMcheck) using the correct city and the 2018 IECC.
2. Correct General Note #7, sheet M101; The controlling code is the 2018 IMC as amended by the City of Tucson.
3. Provide calculations (e.g. COMcheck) for the building envelope to demonstrate compliance with the energy code; use the climate zone for Tucson. Provide sufficient detail on the drawings to evaluate the energy compliance of the building envelope. As a minimum, the information shall include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation and the SHGC for the fenestration. Reference: Sections C103.2 and C401.2, International Energy Conservation Code 2018.
4. Provide heating/cooling load calculations for the building. Reference: Section C403.1.1, IECC 2018.
05/01/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Provide the minimum plumbing facilities required by Table 2902.1, IBC 2018, for storage occupancy.
2. Verify that the total travel distance from any point in the storage building to restroom facilities does not exceed 500-feet. Reference: Section 2902.3.3, IBC 2018.
05/20/2020 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
05/21/2020 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please address the following electrical plan review comments. Also provide a written response.
1. Please revisit the Outdoor Lighting Lumen Calcs, Plan Sheet E101. The data is incorrect.
(a) Per plan sheet A0.0 Project Information Sheet, the parcel size is 4.14 acres, not 5.03 acres. Revise calculations.
(b) Verify that the luminaire lamp color temperature output does not exceed 3500 Kelvin per section 402.1 of the Outdoor Lighting Code (OLC).
2. Ref; Lighting Comcheck needs to be re-vised to the currently adopted 2018 IECC.
3. Show the locations of the electrical breaker panels on the electrical floor plans for each building.
4. Provide GFI protected maintenance receptacles for the mechanical equipment as required pro NEC art 210.63. Buildings A and B.
Ref; 2018 IBC sec, 107.2.1, 2017 NEC, 2018 IECC, City of Tucson Commercial Plan Submittal Requirements, 2012 Tucson/Pima County Outdoor Lighting Code.