Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T19CM03070
Parcel: 137055270

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T19CM03070
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/01/2019 MARTIN BROWN FIRE REVIEW Approved
05/07/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Provide an automatic faucet for the restroom lavatory (LAV-7), dispensing a maximum of 0.25 gallons per metering cycle. Verify that the automatic faucet will operate for at least 10-seconds for accessibility. Reference: Section 419.6, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09.
2. Revise detail L/P03.01 to show a vacuum relief valve instead of a vacuum breaker for the water heater. Reference: Section 504.2, IPC 2018.
05/07/2019 ROBERT SHERRY WATER REVIEW Completed
05/08/2019 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Cover Sheet A00.0 - Code Synopsis - the Restroom Requirements does not specify a service sink as required . Add service sink to Restroom Requierements . IBC Table 2902.1.
2. Sheet S05.01 - Provide Structural Calculations for the Mechanical Support Framing .IBC 107.2.1.
-- Please respond to plan review comments in writting .--
05/08/2019 PMARTIN1 MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. Provide justification for installing HVAC units having a total cooling capacity that exceeds the total cooling load shown in the submitted calculations. Reference: Section C403.3.1, IECC 2018.
2. Demonstrate energy code compliance for the alterations to the building envelope based on the current code (e.g. COMcheck). Reference: Sections C503.1 and C503.3, IECC 2018.
3. Provide calculations to verify that adequate ventilation will be provided for the occupied spaces. (Note that the City of Tucson has not adopted ASHRAE Standard 62-1 as an approved method for calculating ventilation requirements.) Reference: Section 401.2, IMC 2018.
05/29/2019 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please address the following electrical plan review comments. Also provide a written response.
1. Provide full compliance with the 2012 Tucson/Pima County Outdoor Lighting Code for the storefront LED lighting panels. Provide manufacturer cut sheets , indicate light source color output temperature and lumen calcs as outlined per section 104 of this code. This code can be printed or downloaded from www.tucsonaz.gov/pdsd.
Ref; 2012 Tucson/Pima County Outdoor Lighting Code, 2018 IBC sec 107.2.1.

Final Status

Task End Date Reviewer's Name Type of Review Description
06/21/2019 AVAUGHN1 REJECT SHELF Completed