Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T19CM02203
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/11/2019 | DMCCART1 | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T19cm02203 duplex PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Specific Provide R38 Insulation , plan states only 30 Framing plan missing shear panel at corners of walls. Top of page unit. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. PLUMBING PLANS Gray water City of Tucson Amendments to the 2018 IRC;ADD new Section P2601.2.1 AND Table P2601.2, as follows: Section P2601.2.1 Gray water piping. 1. All new residential dwelling units shall include piping to allow separate discharge of gray water for direct irrigation in accordance with Table 2601.2. When feasible, all gray water discharge piping shall be installed to allow for gravity distribution. 2. All gray water systems shall be designed and operated according to the provisions of the applicable permit authorized by ADEQ under the Arizona Administrative Code, Title 18,Chapter 9. a. Available distribution area is the area of the parcel excluding areas within ten (10)feet of load-bearing foundations, two (2) feet of property lines, utility or drainageeasements, driveways, and not covered by permanent impervious surfaces such asparking pads and patios. b. For purposes of this Section, gray water fixtures are defined as bathing fixtures (such as bathtubs and showers) and clothes washing machines. c. For purposes of this Section, fixtures roughed in below a slab on grade are considered below grade, regardless of the soil elevation on the perimeter of the structure. d. Clothes washing machines located in rooms on grade, with no walls common to theexterior of the structure are not required to be supplied with gray water piping. 2012 Tucson/ Pima County Outdoor Lighting Code (OLC); Show that all exterior light fixtures comply with OLC The purpose of this code is to preserve the relationship of the residents of the City of Tucson, Arizona and Pima County, Arizona to their unique desert environment through protection of access to the dark night sky. Intended outcomes include continuing support of astronomical activity 2018 IRC 303 Mechanical Ventilation IRC 303.4 Whole House mechanical ventilation Provide (an HVAC system with) whole-house mechanical ventilation with continuous or a minimum controlled intermittent airflow rate, R303.4 & M1505. Show a source of outside supply air or continuous exhaust fan function. Or show with blower door test greater than 5 air changes per hour. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |