Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T19CM02056
Parcel: 132131010

Address:
2985 S KINO PW

Review Status: Completed

Review Details: COMMERCIAL - NEW

Permit Number - T19CM02056
Review Name: COMMERCIAL - NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/30/2019 MROSS2 FIRE REVIEW Approved
04/30/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Needs Review
04/30/2019 ROBERT SHERRY WATER REVIEW Reqs Change 1. The water utility contact is Tucson Water; New Services, Ray Muñoz (520-837-2207).
2. Reduced pressure backflow prevention assemblies are required to be installed directly after the water meter for buildings that have food service facilities and in locations accessible to Tucson Water. See your civil plans (C9) for an acceptable location. Reference: Chapter XXVII, Article V, Section 27-72, the Tucson Code, http://www.tucsonaz.gov/files/water/docs/backflow-ordinance.pdf
3. The civil utility plan, C9, Calls for a 2" water meter and a 2" water service to the building while the plumbing schedule and drawings call for a 1-1/2" water service. Coordinate the civil and plumbing drawings. Reference: Section 107.2.1, IBC 2018.
4. Include the civil drawings needed to install the on-site utilities as part of the building documents. An approved development plan is not to be used for construction or modification of on-site utilities (e.g. water service to buildings, building sewers, site lighting, electrical service to buildings, etc.).
05/02/2019 PMARTIN1 ELECTRICAL-COMMERCIAL REVIEW Needs Review
05/02/2019 PMARTIN1 ZONING REVIEW Needs Review
05/02/2019 PMARTIN1 BUILDING-COMMERCIAL REVIEW Needs Review
05/02/2019 PMARTIN1 ENGINEERING REVIEW Needs Review
05/02/2019 PMARTIN1 MECHANICAL-COMMERCIAL REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
05/02/2019 PMARTIN1 OUT TO CUSTOMER Completed