Permit Number - T19CM01210
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
02/19/2019 ANDREW CONNOR ZONING REVIEW Reqs Change FROM: Andrew Connor
Planner

PROJECT:
T19CM01210
431 W Rosales
New SFR

TRANSMITTAL: 02/19/2019
COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8).

This site is located in the HR-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a).

The applicant is proposing a new 24' tall SFR with a side yard setback of 5' to the East and West the front street setback proposed is 12'. The required setback to the side and rear would be 15.84'.

345
02/19/2019 ANDREW CONNOR NPPO REVIEW Passed
02/19/2019 ANDREW CONNOR ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: Nicholas Martell
Planner

PROJECT:
431 W Rosales
New SFR

TRANSMITTAL: 12/03/19
COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8).

This site is located in the HR-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a).

Historic review is required. Applicant is proposing reduced setbacks through historic review process. Required setback to the east is 8'-2". Proposed setback to the east is 5'-0". Required setback to the west is 8'-2". Proposed setback to the west is 3'-0". Required setback to the street is 20'-0". Proposed setback is 9'-0".
02/19/2019 ANY BUILDING-RESIDENTIAL REVIEW Active
12/03/2019 NMARTEL1 ENGINEERING REVIEW Passed