Permit Number: T19CM01108
Parcel: 12302067A

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T19CM01108
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/02/2019 DMCCART1 BUILDING-RESIDENTIAL REVIEW Reqs Change T19CM01108
Review Comments
Clarify Structural engineer is for Framing for all building i.e. piers, post, beam, walls, roof. Not just foundation. Revise note at stamp
Page A2:
1. Wind speed revise to 110 mph
2. Code references revise to 2018 IRC

A2.1
1. IRC 404.1.6; Foundation walls shall extend 6 inches above finished grade. Maintain same minimum for bottom of wall
2. Provide Exterior Wall cladding detail at bottom of wall if clay (stucco) then requires weep screed. Include size of flashing.
3. Show how non bearing walls will be attached to foundation. Lag bolts imply wood, however earth bermed. Will the top course of foundation be filled with concrete,
A.3
1. Grade at bottom of wall see note A2.1 item 1
04/19/2019 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T19CM01108
2232 N Forgeus Ave
New Green House
Residential (2nd Review)

TRANSMITTAL DATE: April 19, 2019

1. The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. Until development package DP18-0170 is approved Zoning cannot approve the building plans.

3. Provide proof of a permits for the "EXISTING GUEST QUARTERS" shown on the plan.

4. Until the building plans are approved by all other PDSD review agencies Zoning cannot approve.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
04/19/2019 SSHIELD1 ENGINEERING REVIEW Reqs Change The Development Package must be approved first.

Final Status

Task End Date Reviewer's Name Type of Review Description
04/25/2019 QJONES1 APPROVAL SHELF Completed
04/25/2019 QJONES1 OUT TO CUSTOMER Completed
04/25/2019 QJONES1 REJECT SHELF Completed