Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T19CM00903
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/21/2019 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 11/22/2019 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | The COMcheck component description calls out R19 cavity insulation in the walls along with R-25 continuous insulation. The R-19 cavity insulation is shown in the building sections but the continuous insulation is not shown. Similarly, the roof insulation on COMcheck does not match the drawings. [Initial comment: Provide calculations for the building envelope to demonstrate compliance with the energy code (e.g. COMcheck - the information on sheet T1.2 appears to be for a different building). Provide sufficient detail on the drawings to evaluate the energy compliance of the building envelope. As a minimum, the information shall include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation and the SHGC for the fenestration. Reference: Sections C103.2 and C401.2, International Energy Conservation Code 2018.] |
| 11/22/2019 | RMCCOY1 | BUILDING-COMMERCIAL | REVIEW | Approved |