Permit Review Detail
Review Status: Active
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T19CM00262
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/14/2019 | ANDREW CONNOR | ZONING | REVIEW | Reqs Change | FROM: Andrew Connor Planner PROJECT: T19CM00262 223 N 2ND Ave. Conversion from SFR to Duplex TRANSMITTAL: January 14, 2019 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-3 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a). The applicant is proposing conversion of a single-family residence to a duplex the maximum height of the structure is 23' 10" The proposed setback is 4' 7" to the South and a front yard setback of 9' 9". The required side yard setback would be 15.2' |
| 01/14/2019 | ANY | ENGINEERING | REVIEW | Active | |
| 01/14/2019 | ANY | NPPO | REVIEW | Active | |
| 01/14/2019 | ANY | BUILDING-RESIDENTIAL | REVIEW | Active | |
| 01/14/2019 | ANDREW CONNOR | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: Paul Camarena Planner PROJECT: T19CM00262 223 N 2nd Ave Second floor addition TRANSMITTAL: August 14, 2019 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-3 zone (UDC 4.7.12). A single-family residence is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7. B.6. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). On the south the required setback is 13' 11" based on a wall height of 20' 10". The proposed setback is 6' 4". The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a). On the East the required setback is 22' 6" based on a wall height of 15'. The proposed setback is 17' 9". A DDO is required. |