Permit Review Detail
Review Status: Completed
Review Details: WALLS
Permit Number - T19BU00517
Review Name: WALLS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/14/2019 | SAMUEL ROGERS | ZONING | REVIEW | Reqs Change | FROM: Samuel Rogers - Planner PDSD Zoning Review Section PROJECT: T19BU00517 CMU Perimeter Wall (1st Review) 247 W. 4th St TRANSMITTAL DATE: 1.16.2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Based on a wall height of 11' 4" address the following comments: 01. COMMENT: This plan submittal does not match DP19-0201. A variance will not be able to be processed until the plan set matches the DP. The plan has been reviewed for consistency with the structural plan. It does not appear that the DP plans as it relates to the perimeter walls are consistent. The walls do not meet section 6.6.2.J of the UDC because they do not comply with the perimeter yard standards. A Board of Adjustment Variance is required for the wall setbacks. Include a general note that provides the following information related to the Board of Adjustment Variance; case number, Date of approval and conditions of approval.(List as reference next to the title block the Board of Adjustments case number) 02. Comment: The required setback on Eleventh Ave is 20' or 1 ½ times the height of the wall whichever is greater. (Zoning is considering 11 Ave as the Front Street and 4th and 5th streets as side streets) The proposed setback is Zero. 03. Comment: The required setback on 4th street is 10'. The proposed setback is Zero. 04. Comment: The required setback on the North East 132 linear feet portion of the property is adjacent to the R-3 zone, the required setback is 1 ½ times the height of the wall. The proposed setback is Zero. 05. Comment: The required setback for the South East portion of the property along 5th Street the required setback is 10'. A portion of the wall along the South East is in the 10ft setback. 06. Comment: It is suggested that access on the North East portion should be accessed through the alley. In order to provide access along the North East portion of the property approval by the Department of Transportation is required Per UDC section 6.6.2.J - In nonresidential zones, walls or fences, as permitted in Section 6.6.2.I above, may exceed the height standards, provided the wall or fence complies with the perimeter yard standards applicable to buildings on the site; 07. Comment: Per UDC section 7.10.5 "The use of alleys for vehicular maneuvering or loading is prohibited, unless specifically permitted by Section 7.4.6.K, Use of Street or Alley for Maneuvering Area, or another section of this article." A Board of Adjustments Variance is required. If you have any questions about this transmittal, Contact Samuel Rogers at (520) 837-6932 or by email Samuel.Rogers@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans |
| 10/14/2019 | RMCCOY1 | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 10/14/2019 | SROGERS2 | NPPO | REVIEW | Passed | |
| 10/15/2019 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 10/15/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Passed |