Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T19BU00365
Parcel: 99999999B

Review Status: Completed

Review Details: BILLBOARD - BLDG30days

Permit Number - T19BU00365
Review Name: BILLBOARD - BLDG30days
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/03/2019 GLENN MOYER ADMINISTRATIVE ADMIN REVIEW Denied Below are comments on the authorized repair resubmittal for COT ID# 257 at 1315 East Valencia Road (T19BU00365 R).

Sheet 1 of 4
None

Sheet 2 of 4
1. In 8th & 9th paragraphs of Scope of Work-East Face, revise apron height as necessary (see Comment #5 below for Sheet 3 of 4)
2. Delete orphan 11th paragraph of Scope of Work-East Face, as it has been supplanted by added 12th paragraph of Scope of Work-East Face.
3 In 6th paragraph of Scope of Work-West Face, revise spacer thickness reflect to conform to the balance of the plan.
4. Add paragraph to Scope of Work-West Face to reflect the reattachment of ballast detached per the added 4th paragraph of Scope of Work-West Face above.
5 Delete orphan 8th paragraph of Scope of Work-West Face, as it has been supplanted by 7th paragraph above.
6. In 1st paragraph of Poster Panel notes, delete language within cloud per engineer’s response on Comment #7 for this sheet.

Sheet 3 of 4
1. In Poster Panel Side View, revise the two references to panel clips to conform with the existing panel clips (as indicated in the 5th paragraph of Poster Panel Notes on Sheet 2 (Engineer’s Response letter for Comment #1 on Sheet 3 indicates that these references were revised, but the revised plan sheet does not reflect any changes to this detail).
2. In the titles for Poster Panel Side View and each of Details A-D, add east face or west face, as applicable, for clarity (Engineer’s Response letter for Comment #2 on Sheet 3 indicates that these references were added, but the revised plan sheet does not reflect these changes having been made).
3. In Details A & B, the spacer thickness was revised per Comment #3 on Sheet 3, but not accompanied with a revision cloud; please cloud these two changes as a first revision.
4. In title of Light Mounting Detail., clarify if it is applicable to west face only (Engineer’s response Letter indicates this clarification was made, but such change is not reflected in the resubmitted plan sheet).
5. In Apron Mounting Detail and Side view (East Face), the top of the apron is depicted to be flush with the bottom of the plywood face panel, where in the existing installation approximately nine inches of the apron extends vertically behind the plywood sheet panel and the overall height is less than 12 feet; revise both details to reflect the existing installation and any reduction in apron height as applicable. (Note the original comment #9 ion this sheet inadvertently had a secondary reference to Poster Panel (Side View) rather than Side View East Face, but the primary reference to Apron Mounting detail clearly applies to the east face and should be so labeled).

Sheet 4 of 4
1. In added Light Mounting Detail (Side View), indicate which face (west or east).
2. Revise Description of New Lamp to Description of Existing Lamp.

Final Status

Task End Date Reviewer's Name Type of Review Description
02/06/2020 SBORZAK1 OUT TO CUSTOMER Completed