Plan Review Detail
Review Status: Completed
Review Details: REZONING - ZE HEARING
Plan Number - T18SE00067
Review Name: REZONING - ZE HEARING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/04/2019 | PMCLAUG1 | ENGINEERING | REVIEW | Completed | |
| 02/04/2019 | PMCLAUG1 | ENV SVCS | REVIEW | Completed | |
| 02/04/2019 | PMCLAUG1 | DOT ENGINEERING | REVIEW | Completed | |
| 02/04/2019 | PMCLAUG1 | COMMUNITY PLANNING | REVIEW | Completed | |
| 02/04/2019 | PMCLAUG1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | |
| 02/04/2019 | PMCLAUG1 | REZ AGENCY REVIEW | PARKS & RECREATION | Completed | |
| 02/04/2019 | PMCLAUG1 | REZ AGENCY REVIEW | OFFICE OF CONSERVATION & SUSTAINABLE DEVELOPMENT | Completed | |
| 02/04/2019 | PMCLAUG1 | REZ AGENCY REVIEW | PIMA ASSN OF GOVTS | Completed | |
| 02/04/2019 | PMCLAUG1 | REZ AGENCY REVIEW | PIMA CNTY WASTEWATER | Completed | |
| 02/04/2019 | PMCLAUG1 | REZ AGENCY REVIEW | SCHOOL DISTRICT | Completed | |
| 02/04/2019 | PMCLAUG1 | REZ AGENCY REVIEW | ADOT | Completed | |
| 02/04/2019 | PMCLAUG1 | REZ AGENCY REVIEW | TDOT RTA | Completed | |
| 02/04/2019 | PMCLAUG1 | REZ AGENCY REVIEW | TDOT STREETS | Completed | |
| 02/04/2019 | PMCLAUG1 | REZ AGENCY REVIEW | OTHER AGENCIES | Completed | |
| 11/19/2018 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC TRANSMITTAL TO: Development Services Department Rezoning Section FROM: Elisa Hamblin, AICP Principal Planner PROJECT: 8019 E Golf Links Rd Parcel: 136156150 Zoning: C-1 Zone T18SE00067 (SE-18-67) Mayor and Council Special Exception Procedure TRANSMITTAL: November 19, 2018 The proposed commercial use falls under UDC Article 4.8.6, Table 4.8-4: Permitted Uses - Commercial and Mixed Use Zones. Commercial Land Use Group with Land Use Class/Type: Medical Care: Outpatient, limited to blood donor centers subject to Use Specific Standards 4.9.4.O.3 and 4.9.13.O. Vehicular Access: = Vehicular access appears to be adequate Vehicle Parking Required = 76 spaces (1 / 200 sq. ft. GFA) Vehicle Parking Provided = 106 spaces Short Term Bicycle Required = 3 spaces (1 / 5,000 sq. ft. GFA, Min. 2 spaces) Short Term Bicycle Provided = 9 spaces Long Term Bicycle Required = 2 spaces (1 / 12,000 sq. ft. GFA. Min. 2 spaces) Long Term Bicycle Provided = None provided Off-Street Loading Required = Not required Off-Street Loading Provided = 1 loading area on west of building Pedestrian Access: = Does not meet standards, a sidewalk is required adjacent to the building and between any vehicle access lane Allowed Building Height: = 30' Proposed Building Height: = 23'2" Should you have questions, please contact me at (520)837-4966 or elisa.hamblin@tucsonaz.gov. |
| 11/19/2018 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Completed | November 19, 2018 ACTIVITY NUMBER: T18SE00067 PROJECT NAME: Biolife Plazma PROJECT ADDRESS: 8019 E golf Links Road PROJECT REVIEWER: Zelin Canchola TDOT TDOT offers the following comment: 1. No adverse comments. Maintain existing condition in the special exception/rezoning that the 5-foot strip is preserved and remains as public right of way. 5 foot right of way per BK 63 PG 41 PCR If you have any questions, I can be reached at 520 837 6659 or zelin.canchola@tucsonaz.gov |
| 11/21/2018 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | The following applies: ADMINISTRATIVE MANUAL SECTION 2-10.0.0: LANDSCAPE PLAN SUBMITTAL REQUIREMENTS SECTION 7.6.4. LANDSCAPE STANDARDS |
| 11/21/2018 | HEATHER THRALL | SIGNS | SIGN CODE REVIEW | Passed | |
| 11/21/2018 | MARTIN BROWN | FIRE | REVIEW | Approved |