| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/09/2018 | ANY | DOT ENGINEERING | REVIEW | Active | |
| 10/09/2018 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Active | |
| 10/15/2018 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | NPPO and Mitiagtion plans should be submitted with Development Package. |
| 10/18/2018 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 10/22/2018 | EHAMBLI1 | ZONING | REVIEW | Completed | CDRC TRANSMITTAL TO: Development Services Department Rezoning Section FROM: Elisa Hamblin, AICP Lead Planner PROJECT: 10201 S Swan Rd Parcel: 303-70-0005A Zoning: RH Zone T18SE00064 Mayor and Council Special Exception Procedure TRANSMITTAL: October 22, 2018 The proposed utility use falls under UDC Article 4.8.3, Table 4.8-1: Permitted Uses - Rural and Suburban Residential Zones. Utility Land Use Group with Land Use Class/Type: Distribution System: Limited to Power Substation (Input Voltage of 115 Kilovolts or Greater) subject to Use Specific Standards 4.9.11.A.3, .6, .7, & .10 and 4.9.13.I. Vehicular Access: = Vehicular access appears to be adequate Vehicle Parking Required = 2 spaces per facility Vehicle Parking Provided = 0 Short Term Bicycle Required = None required Short Term Bicycle Provided = Not provided Long Term Bicycle Required = None required Long Term Bicycle Provided = Not provided Off-Street Loading Required = None required Off-Street Loading Provided = Not provided Pedestrian Access: = Pedestrian Access appears to be adequate Allowed Building Height: = 30' Proposed Building Height: = Equipment and structures up to 80' |
| 10/31/2018 | PMCLAUG1 | ENGINEERING | REVIEW | Completed | |
| 10/31/2018 | PMCLAUG1 | ENV SVCS | REVIEW | Completed | |
| 10/31/2018 | HEATHER THRALL | SIGNS | SIGN CODE REVIEW | Completed | |
| 10/31/2018 | PMCLAUG1 | COMMUNITY PLANNING | REVIEW | Completed | Background: This is a Special Exception request by TEP to construct a new 138/46/13.8 kV substation and associated facilities to facilitate solar development interconnection, provide future power supply for planned growth in the area, and provide contingency for the power system. The proposed site is a vacant 52.14 acre parcel south of the Swan Road and Old Vail Connection Road intersection. Swan Road is classified as Arterial Roadways on the Major Streets and Routes Plan map. Surrounding Zoning and Land Uses: The property is surrounded by RH zoning to the north, east, south and west, with uses to the east - vacant land/prison, to the west - vacant and residences, to the north - vacant and gravel pit, and to the south - vacant, utility, and residential. APPLICABLE PLAN POLICIES: Plan Tucson: Supports the coordination with utility companies and other public service providers fort he planning of infrastructure, facilities, and services, making sure infrastructure and facility construction is sensitive in design and location to environmental and historic resources. PT also provides policy direction in the improvement and the appearance of above-ground utilities and structures, and supports extending access to high-tech wireless communications facilities throughout the city. Note that the Rincon Subregional Plan does call out this site in any of the Map Details and thus does not provide for any specific land use policy guidance. Analysis: Plan Tucson supports utility upgrades. The proposed project does not require a plan amendment. |
| 10/31/2018 | PMCLAUG1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | |
| 10/31/2018 | PMCLAUG1 | REZ AGENCY REVIEW | PARKS & RECREATION | Completed | |
| 10/31/2018 | PMCLAUG1 | REZ AGENCY REVIEW | OFFICE OF CONSERVATION & SUSTAINABLE DEVELOPMENT | Completed | |
| 10/31/2018 | PMCLAUG1 | REZ AGENCY REVIEW | PIMA ASSN OF GOVTS | Completed | |
| 10/31/2018 | PMCLAUG1 | REZ AGENCY REVIEW | PIMA CNTY WASTEWATER | Completed | |
| 10/31/2018 | PMCLAUG1 | REZ AGENCY REVIEW | SCHOOL DISTRICT | Completed | |
| 10/31/2018 | PMCLAUG1 | REZ AGENCY REVIEW | ADOT | Completed | |
| 10/31/2018 | PMCLAUG1 | REZ AGENCY REVIEW | TDOT RTA | Completed | |
| 10/31/2018 | PMCLAUG1 | REZ AGENCY REVIEW | TDOT STREETS | Completed | |
| 10/31/2018 | PMCLAUG1 | REZ AGENCY REVIEW | OTHER AGENCIES | Completed |