Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T18PI00041
Parcel: Unknown

Review Status: Completed

Review Details: PIA - RESUBMITTAL

Plan Number - T18PI00041
Review Name: PIA - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/21/2019 GARY WITTWER DOT LANDSCAPE REVIEW Approv-Cond How will the median island be watered? Water truck?
Please add my standard notes for planting in ROW. If you do not have them - please e-mail me and request them.
04/10/2019 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Needs Review
04/10/2019 RICHARD LEIGH DOT ENGINEERING REVIEW Approv-Cond April 10, 2019


SUBJECT: Silverbell Crossing - Phase B, Paving Plans - T18PI00041

PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section

RESUBMITTAL REQUIRED: TDOT Technical Review Section has reviewed the PIA paving plan and recommends a conditional approval at this time. The following comments need to be addressed prior to submittal of the mylar plan set for signatures. Please email a PDF copy of the revised plans for final review prior to submitting mylars.

1. Use TDOT engineering plan template for this plan set. The latest TDOT engineering plan template can be found at https://www.tucsonaz.gov/tdot/engineering. If you have any questions please call me.

2. Sheet 4, Detail 1: Barricade railing is not required on curb side of side walk scupper. Revise detail to indicate this.

If you have any questions, I can be reached at 837-6647 or emailed at Richard.Leigh@tucsonaz.gov.
04/10/2019 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSADOR Completed Please submit utility confgirmation receipts.
04/10/2019 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Needs Review
04/10/2019 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed Please submit utility confgirmation receipts.
04/10/2019 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Needs Review
04/10/2019 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Needs Review
04/10/2019 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Needs Review
04/10/2019 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Needs Review
04/10/2019 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Needs Review
04/10/2019 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Needs Review
04/10/2019 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Needs Review