Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T18PI00037
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/07/2019 | LPETERS2 | DOT PERMITS & CODES | REVIEW | Denied | I have reviewed this plan and have the following comments: 1. Sheet 2 note 31 - This note relates to the work for the development. There needs to be a note referenceing work in the right of way requires a permit and coordination with a Transportation Construction Inspector. 2. I did not see mention of disturbing city of tucson landscaping and irrigation. There should be a note calling for the contractor to coordinate any repair or relocation if city owned irrigation and vegetation with Paul Rosenboom of our Strets and Traffic Maintenance Division 3. Sheet 4 - There is no survey information (stations and outs) provided to locate driveways, curb returns, or curb access ramps. No further comments. Lance |
| 01/08/2019 | JIM FEMLING | DOT STREET MAINTENANCE | REVIEW | Completed | 01/08/2019 - per JFemling, no comments |
| 01/08/2019 | FSHENK1 | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 01/08/2019 | FSHENK1 | PIA COORDINATOR | OUT TO CUSTOMER | Completed | |
| 11/26/2018 | FSHENK1 | UTILITY CLEARANCES | COT STREETS DIVISION | Needs Review | |
| 12/05/2018 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | TDOT has landscape and irrigation in both the shoulder and the median on Harrison. All plants that are removed must be mitigated and the irrigation must be addressed. The new entry drive will need to provide 4' PVC Sch 40 sleeving for what ever irrigation lines are located there. Existing lines must be placed in new sleeving. There also may be valve wires at this location. |
| 12/17/2018 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Reqs Change | December 17, 2018 SUBJECT: T18PI00037 Offsite Improvement plan for Halcyon Acres PROJECT REVIEWER: Zelin Canchola, TDOT Review Section RESUBMITTAL REQUIRED: DOT Review Section has reviewed the PIA Plan for Traffic Engineering. The proposed plan requires the following change: Striping Plan: 1. Review of striping plan required. Plan as shown not acceptable. If you have any questions I can be reached at 837-6659 or zelin.canchola@tucsonaz.gov |
| 12/19/2018 | FSHENK1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Completed | |
| 12/19/2018 | FSHENK1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Completed | |
| 12/19/2018 | FSHENK1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Completed | |
| 12/19/2018 | FSHENK1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Completed | |
| 12/19/2018 | FSHENK1 | UTILITY CLEARANCES | COX COMMUNICATION | Completed | |
| 12/19/2018 | FSHENK1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Completed | |
| 12/19/2018 | FSHENK1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Completed | |
| 12/19/2018 | FSHENK1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Completed | |
| 12/28/2018 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Reqs Change | December 28, 2018 SUBJECT: Offsite Improvements for Halcyon Acres Block 1 PROJECT REVIEWER: Richard Leigh, TDOT Engineering Review RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to final approval. Please include a response letter addressing the following comments and return any redlined drawings with subsequent submittal. 1. Sheet 1: Include the plan number "U-2018-014" in the title block of each sheet. 2. Sheet 1: Include the PIA activity number "T18PI00037" on cover sheet. 3. Sheet 2: Clearly indicate beginning of proposed curb (new to existing) and label with stationing and elevations. 4. Label proposed curb access ramps with PAG standard detail. 5. Sheet 2, Keynote 10: Per SMDD 10.9.1.8 a M.H shall be provided at angle points greater than 10 degrees. Indicate the placement of a M.H at junction of new to existing storm drain. 6. Sheet 2, Keynote 8: Proposed replacement catch basin shall match existing. Refer to TDOT plan number I-2002-004 for details. 7. Sheet 2, keynote 9: Per SMDD 10.3.9 storm drain pipe in the public ROW shall be reinforced concrete pipe. Indicate class of RCP, pipe slope and pipe length. 8. Sheet 2: Indicate that the pedestrian crosswalk area across new driveway will have a cross slope no greater than 2%. 9. Please Refer to redline drawings for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or emailed at Richard.Leigh@tucsonaz.gov. |