Plan Number: T18PI00017
Parcel: Unknown

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T18PI00017
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/24/2018 TWOLFGA1 UTILITY CLEARANCES COT STREETS DIVISION Completed
08/07/2018 JIM FEMLING DOT STREET MAINTENANCE REVIEW Completed
08/07/2018 RICHARD LEIGH DOT ENGINEERING REVIEW Reqs Change July 20, 2018

SUBJECT: Houghton Town Center Phase 2A Offsite Improvements

PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section

RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval at this time. The following comments need to be addressed prior to in the subsequent review submittal. Please return redlined drawings with next submittal.

1. Use TDOT engineering plan template for this plan set. The latest TDOT engineering plan template can be found at https://www.tucsonaz.gov/tdot/engineering.

2. Include the plan number "U-2018-005" in the title block of each sheet.

3. Include PIA activity number "T18PI00017" on cover sheet.

4. Include Development Plan number on cover sheet.

5. Sheet 2: Locate proposed curb access ramp on the east side of driveway to be more in line with ramp across driveway.

6. Sheet 4:, Detail A: Provide a geotechnical analysis supporting proposed pavement section or use pavement structural section "1" called out in Houghton / Old Vail Road Intersection Improvements plans I-2009-003 Sheet 9 of 108.

If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov.
08/07/2018 ZELIN CANCHOLA DOT TRAFFIC REVIEW Approved
09/04/2018 ERNIE ENCINAS DOT_ELEC REVIEW Needs Review
09/04/2018 TWOLFGA1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Denied
09/04/2018 TWOLFGA1 PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
09/04/2018 TWOLFGA1 UTILITY CLEARANCES PC WASTEWATER MGMT Denied
09/04/2018 TWOLFGA1 PIA COORDINATOR OUT TO CUSTOMER Denied
09/04/2018 TWOLFGA1 UTILITY CLEARANCES QUEST COMMUNICATION Denied
09/04/2018 TWOLFGA1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Denied
09/04/2018 TWOLFGA1 UTILITY CLEARANCES COX COMMUNICATION Denied
09/04/2018 TWOLFGA1 UTILITY CLEARANCES SOUTHWEST GAS CORP Denied
09/04/2018 TWOLFGA1 UTILITY CLEARANCES EL PASO NATURAL GAS Denied
09/04/2018 TWOLFGA1 UTILITY CLEARANCES KINDER MORGAN ENERGY Denied