Plan Number: T18PI00005
Parcel: Unknown

Address:
192 S STONE AV

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T18PI00005
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/07/2018 GARY WITTWER DOT LANDSCAPE REVIEW Denied All plants within the ROW must be on the approved plant list. I don't believe Asparagus Fern, Creaping Fig and Indian Hawthorn are on that list.

You must also add the TDOT Standard Notes for planting in the ROW to you drawing. If you don't have them let me know. Gary 837-6618
02/26/2018 LINZUNZA UTILITY CLEARANCES COT STREETS DIVISION Completed
02/26/2018 LINZUNZA UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Completed
02/26/2018 LINZUNZA UTILITY CLEARANCES PC WASTEWATER MGMT Completed
02/26/2018 LINZUNZA UTILITY CLEARANCES QUEST COMMUNICATION Completed
02/26/2018 LINZUNZA UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Completed
02/26/2018 LINZUNZA UTILITY CLEARANCES COX COMMUNICATION Completed
02/26/2018 LINZUNZA UTILITY CLEARANCES SOUTHWEST GAS CORP Completed
02/26/2018 LINZUNZA UTILITY CLEARANCES EL PASO NATURAL GAS Completed
02/26/2018 LINZUNZA UTILITY CLEARANCES KINDER MORGAN ENERGY Completed
03/05/2018 ZELIN CANCHOLA DOT TRAFFIC REVIEW Approved
03/08/2018 RICHARD LEIGH DOT PERMITS & CODES REVIEW Approv-Cond No Comments at this time
03/08/2018 RICHARD LEIGH DOT ENGINEERING REVIEW Reqs Change March 2, 2018

SUBJECT: Offsite Improvements for Saint Augustine Cathedral - Ochoa Street

PROJECT REVIEWER: Richard Leigh, TDOT Engineering Review

RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to final approval. Please include a response letter addressing the following comments and return any redlined drawings with subsequent submittal.

1. Sheet 1: Include the plan number "I-2018-004" in the title block of each sheet.

2. Sheet 1: Include the PIA activity number "T18PI00005" on cover sheet.

3. Sheet 1: Reference Development Plan Number on cover sheet.

4. Sheet 1: Paving note 2: Revise note to remove building references and include roadway infrastructure.

5. Sheet 1 Paving note 13: Revise phone number for Paul Rosenboom to 520-791-3154 .

6. Sheet 2: Clearly indicate beginning of proposed curb (new to existing) and label with stationing.

7. Sheet 2: Indicate recording sequence number for right-of-way acquisition.

8. Sheet 2, keynote 14: Indicate class of RCP, pipe slope and pipe length.

9. Sheet 2, Keynote 19: Reference applicable specification or provide complete details for proposed PCCP.

10. Sheet 4: Per T.S.M . (10-1.4.1.A.1.a), the minimum sidewalk width is 5 feet, (excluding curb and tree grates) also per (10-1.3.3.D.4), a 1foot separation must be provided between the edge of sidewalk and any structure. Revise drawing to provide the minimum COT Technical Standards Manual requirements.

11. Sheet 4: Revise drawing to provide a curb access ramp at the southwest corner of Stone Ave and Ochoa St to provide ADA compliant access for north and south bound pedestrian access.

12. Sheet 4: Indicate that a pedestrian crosswalk area, which has a cross slope less than 2%, will be provided between access ramps at Church Ave and Stone Ave.

13. Sheet 6, Detail 1: Verify location of ROW depicted on section, the stairs should not be located within the public ROW.

14. Sheet 6, Detail C: Dimension detail and indicate concrete type.

15. Provide a geotechnical analysis to support proposed pavement section.

16. For the narrowing of the roadway and the proposed location of the roadway crown, provide a hydraulic analysis for the street capacity and for the new catch basin on Ochoa St.

17 Please Refer to redline drawings for additional comments and comment details.

If you have any questions, I can be reached at 837-6647 or emailed at Richard.Leigh@tucsonaz.gov.
03/12/2018 TWOLFGA1 PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
03/12/2018 JIM FEMLING DOT STREET MAINTENANCE REVIEW Approved
03/12/2018 TWOLFGA1 PIA COORDINATOR OUT TO CUSTOMER Completed