Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T18PI00002
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/09/2018 | LPETERS2 | DOT PERMITS & CODES | REVIEW | Denied | I have reviewed this plas and ahave the following comments: 1. Sheet 2 - Paving note 5 - This note should state, "Aspahlt Concrete shall conform to City of Tucson Mix #2." 2. Sheet 3 - Curb Ramp Details Please refernce PAG 2015 Access Ramp Details and Type. No further comments. Lance Peterson, P.E. (520) 837-6777 |
| 02/01/2018 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Reqs Change | February 1, 2018 SUBJECT: La Estancia Phase 8 T18PI00002 (I-2008-002) PROJECT REVIEWER: Zelin Canchola, TDOT Review Section RESUBMITTAL REQUIRED: DOT Review Section has reviewed the PIA Plan for Traffic Engineering. The proposed plan requires the following change: 1. Add - Street name signs 2. Add - Stop signs 3. Add - No Parking fire access signs If you have any questions I can be reached at 837-6659 or zelin.canchola@tucsonaz.gov |
| 02/13/2018 | LINZUNZA | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | |
| 02/13/2018 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Passed | |
| 02/13/2018 | LINZUNZA | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | |
| 02/13/2018 | CSALTZM1 | DOT ENGINEERING | REVIEW | Denied | SUBJECT: La Estancia De Tucson Phase 8 Public Paving and Drainage Improvements PROJECT REVIEWER: Craig Saltzman, TDOT Engineering Review RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to final approval. Please include a response letter addressing the following comments and return any redlined drawings with subsequent submittal. 1. Sheet 1: Include the plan number "I-2018-002" in the title block of each sheet. 2. Sheet 1: Include the PIA activity number "T18PI00002" on cover sheet. 3. Sheet 1: Location Map - Call outs for City of Tucson and Pima County need to be reversed. Example : The call out for the City of Tucson should be on the west side of the section line. 4. Sheet 2: Revise Paving Note 5 to indicate City of Tucson "City Mix" asphalt Mix #2. 5. Sheet 2: Revise Paving Note 10 to Read: The City shall not be held liable for any errors and/or omissions on these plans items not meeting City Standards. The errors and/or omissions shall be repaired and/or replaced at no cost to the City. 6. Sheet 2: Paving note 15: Revise phone number for Paul Rosenbloom to 520-791-3154. 7. Sheet 3: Detail A: Revise detail to reference placement of curb access ramps per PAG Standard Detail 207, Type 1. 8. Sheet 3: Detail B: Remove from detail the following: "Pedestrian Refuge". 9. Sheet 4 - 8: Indicate placement of survey monuments per PAG Standard Detail 103 at roadway intersections and at the points of curvature along roadway center line 9. Sht. 4: Mid-block access ramp at Sta. 157+80.05 move to Sta. 157+92.48 to align with the access ramp across the road. 10. Sht. 7: Profile - Street center grade - show % slope from the PVI Sta. 294+61.22 to Match Line If you have any questions, I can be reached at 837-6621 or emailed at Craig.saltzman@tucsonaz.gov. |
| 02/13/2018 | LINZUNZA | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | |
| 02/13/2018 | LINZUNZA | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | |
| 02/13/2018 | LINZUNZA | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | |
| 02/13/2018 | LINZUNZA | UTILITY CLEARANCES | COX COMMUNICATION | Denied | |
| 02/13/2018 | LINZUNZA | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | |
| 02/13/2018 | LINZUNZA | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | |
| 02/13/2018 | LINZUNZA | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied | |
| 02/23/2018 | JIM FEMLING | DOT STREET MAINTENANCE | REVIEW | Completed | |
| 02/23/2018 | LINZUNZA | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 02/23/2018 | LINZUNZA | PIA COORDINATOR | OUT TO CUSTOMER | Completed |