Review Date Reviewer's Name Type of Review Description Status Comments
01/08/2019 ANDREW CONNOR ZONING REVIEW Reqs Change FROM: Andrew Connor
Planner

PROJECT:
T18CM00068
1302 E 13th Ave
New 2 story Single Family Residence.

TRANSMITTAL: January 8, 2019
COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The applicant is proposing a new 2 story Single Family Residence with a maximum height of 19' 9" with a proposed setback of 3' 6" to the West and a 6' setback to the East the required setback would be 13.2'