Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T18CM09573
Parcel: 11450023B

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T18CM09573
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/11/2019 KEN VAN KARSEN BUILDING-COMMERCIAL REVIEW Completed
02/05/2019 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T18CM09573
8721 E. Woodland Drive
New SFR
Residential (2nd Review)

TRANSMITTAL DATE: February 5, 2019

The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

This site is located in the SR zone (UDC 4.7.4). A Single Family Residence is an allow use in this zone.

1. Until the grading plan, DP18-0296 is approved Zoning cannot approve the building plans.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
02/06/2019 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change T18CM09573

1) Once DP18-0296 has been approved, the Building Plans can be reviewed and approved.
02/06/2019 ANDREW CONNOR NPPO REVIEW Reqs Change SECTION 4-02.0.0: FLOODPLAIN, WASH AND ERZ STANDARDS.
2.4 Identification of Regulated Areas and Protected Riparian Areas
All tentative plats, site plans, plot plans or other plans providing for approval of development within property that includes any regulated area as defined in Section 4-02.2.2.A, ERZ Watercourses, shall identify and delineate the regulated areas and the protected riparian area on the property and shall comply with this standard. The boundary of the regulated area and the protected riparian area should be clearly depicted on applicable submittal documents.
Encroachment in Regulated Areas
If the project proposes encroachment within the regulated areas, it shall conform to the following.
1. Environmental Resource Report. Applicants are required to submit an Environmental Resource Report as defined in Section 11.4.6 of the UDC. The supporting material for preparation of the Environmental Resource Report is based on information from the Hydrologic Data and Wash Information maps on the Tucson Department of Transportation internet web site: The Critical and Sensitive Wildlife Habitat Map and Report, the Mayor and Council Interim Watercourse Improvement Policy and subsequent adopted policies, the Tucson Stormwater Management Study, the following Basin Management Plans: 1) West Branch, Santa Cruz; 2) Houghton East; 3) Este Wash; and 4) Arroyo Chico. the Tucson Stormwater Management Study, Phase II and field observation. An application may request that an element listed below be waived or that the report address only a specified area where a full report is not applicable to the proposed encroachment. DSD may grant such waivers where the elements or full report are not required by code. The Environmental Resource Report must include: Information indicated 4-02.2.5B a-x.

Submit ERR for review.

Until the grading plan, DP18-0296 is approved NPP cannot approve the building plans.

Final Status

Task End Date Reviewer's Name Type of Review Description
04/02/2019 QJONES1 APPROVAL SHELF Completed
04/02/2019 QJONES1 OUT TO CUSTOMER Completed
04/02/2019 QJONES1 REJECT SHELF Completed