Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T18CM08996
Parcel: 137055330

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T18CM08996
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/30/2018 MCASTRO2 ZONING REVIEW Approved
11/30/2018 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
11/30/2018 JVINCEN1 FIRE REVIEW Approved
11/30/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Comment not addressed [Initial comment: Provide an automatic faucet for the lavatory, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the automatic faucet will operate for a minimum time of 10-seconds. Reference: Section 416.6, IPC 2012, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09.
2. Comment not addressed [Initial comment: Provide tempered water for the lavatories and public hand-washing sinks in restrooms using approved devices conforming to ASSE 1070. Reference: Sections 416.5 and 607.1.2, IPC 2012.
3. Comment not addressed [Initial comment: Clarify how the drinking fountain will be able to serve bot standing and handicapped users. Reference: Section 410.2, IPC 2012.
11/30/2018 MCASTRO2 ENGINEERING REVIEW Passed
11/30/2018 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
12/11/2018 QJONES1 APPROVAL SHELF Completed
12/11/2018 QJONES1 OUT TO CUSTOMER Completed
12/11/2018 QJONES1 REJECT SHELF Completed