Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T18CM08835
Parcel: 13316039A

Review Status: Completed

Review Details: RESUBMITTAL - TI ALL

Permit Number - T18CM08835
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/10/2019 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Previous Comment 1; Sheet TS1; Code Study: Please provide calculations on this sheet for the required plumbing fixtures in Building A. At this time, no indication of required fixtures is presented.
2. Previous Comment 2; Sheet ASP1; Exiting Plans: Please indicate on this sheet the total occupant load for Building A.
3. Previous Comment 6; Sheet A2.2; Second Floor Reflected Ceiling Plan: No exit lighting was indicated on these plans. Please provide.
4. Sheet A2.2; Second Floor Reflected Ceiling Plan: The reflected ceiling plan for the revised open area (as indicated on Sheet A2.1) should be indicated on Sheet A2.2. Please verify.
5. Sheet A3.0; Detail 7: A reference in this detail is made to Section 217/S5.0 for the steel post attachment to the masonry wall. Please revise that reference.
6. General: Please provide written responses to all review comments.

Review by Eric Newcomb
Contact at 520-837-4911 or Eric.Newcomb@tucsonaz.gov
04/19/2019 STEVE SHIELDS ZONING REVIEW Approved
04/25/2019 ROBERT SHERRY WATER REVIEW Completed
04/25/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change The submitted cut-sheets for the shampoo sink do not indicate that it is a listed product. The sink will have to be third party listed or an engineer will have to show that the unit meets all applicable standards as an alternative material or equipment. Reference: Section 105.2, IPC 2012. [Initial comment: Revise the plumbing fixture schedule to require a third party listing for the shampoo sinks (P7) supplied by the owner. Reference: Section 303.4, IPC 2012.]
04/26/2019 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
05/03/2019 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved