Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T18CM08452
Parcel: 126172760

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T18CM08452
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/19/2019 EHAMBLI1 ZONING REVIEW Approved ZONING REVIEW TRANSMITTAL


FROM: Elisa Hamblin, Lead Planner
PROJECT:
T18CM08452, 4210 E Santa Barbara Av
Enclose carport to garage, does not meet setback requirements
TRANSMITTAL: October 30, 2018
COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment (UDC Section 3.10.1).

This site is located in the R-1 zone (UDC 4.7.9). Single-family residential is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7.B.6, .9 & .10.

The applicant is proposing to enclose an existing carport to a garage. The structure is located 3' from the street property line. The minimum required setback is 20' or 1.5 times the height of the structure. Board of Adjustment approval required.
02/19/2019 EHAMBLI1 ENGINEERING REVIEW Passed
02/19/2019 EHAMBLI1 NPPO REVIEW Passed
03/01/2019 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T18CM08452

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

SECTIONS - DETAILS:

1. The plans do not comply with minimum 2012 IRC requirements. Update the cross-section detail of the new exterior wall on sheet #3 and the elevation on sheet #4, R106.1.1. Show the minimum 12" footing depth below the undisturbed ground surface (R403.1) with 12" minimum width for wood framed walls R403.1.1. Show exterior wood siding, sheathing and wall framing with a 6" clearance above the ground (R317.1 item 5) or 2" above a concrete surface. Show a minimum ½" diameter anchor bolt with 7" embedment, R602.10.8 & R403.1.6. Or, add a registered Arizona engineer seal to the non-prescriptive design.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review