Review Details: COMMERCIAL - TI
Permit Number - T18CM08366
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/22/2018 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 10/22/2018 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | Verify the new bar area has adequate ventilation per Section 403.3, IMC 2012. |
| 10/22/2018 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 10/22/2018 | MASHFOR1 | FIRE | REVIEW | Approved | |
| 10/22/2018 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. a 3.0 Revise the door swing at the main entrance to swing in the direction of egress travel due to the occupant load over 50 persons. 2. Specify panic or exit hardware on the esit doors. 3. Show the location of the EXIT signage. 4. If new walls or partitions are being constructed need to provide frame details that show wall stud and wall covering and connection of new walls to the roof/ceiling and floor. 5. The ratio for water closets for male and female for a bar occupancy is 1 per 40, not 1 per 75. IBC TABLE 2902.1 |
| 10/22/2018 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 10/22/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Needs Review | |
| 10/24/2018 | EHAMBLI1 | ENGINEERING | REVIEW | Passed | |
| 10/24/2018 | EHAMBLI1 | ZONING | REVIEW | Approved |