Permit Number: T18CM07922
Parcel: 136414990

Address:
3560 S JESTER CT

Review Status: Completed

Review Details: WALK THRU - RES

Permit Number - T18CM07922
Review Name: WALK THRU - RES
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/09/2018 TWEIDEM1 BUILDING-RESIDENTIAL REVIEW Reqs Change T18CM07922

PLAN REVIEW COMMENTS
Plan review for the above referenced structure is completed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code, 2012 International Fire Code, 2011 National Electrical Code and Arizona Revised Statutes. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

DIAGRAMS / CALCULATIONS
1. Show the sum of the main and backfeed breakers not exceeding 120% of the busbar (and conductor) rating, NEC 690.64 & 705.12 (D). All conductive components between the energy source breakers require this rating. Provide a feeder with a minimum 75 AMP feeder rating, or move the backfeed breaker to the service panel.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
10/09/2018 TOM WEIDEMAN ENGINEERING REVIEW Passed