Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T18CM07899
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/31/2018 | MARTIN BROWN | FIRE | REVIEW | Reqs Change | This residence will have a "fire-flow calculation area"(2018 IFC Appendix B, Section B102 and 105.1) greater than 3,600 sq. ft.: therefore this house will require a residential sprinkler system unless the fire flow in the nearest hydrant is a minimum of 1,750 GPM for 2 hours duration at 20 psi residual pressure. Additionally, the hydrant must be within 600' of all parts of the residence. Contact Tucson Water and request a "modeled" fire flow for this address. Provide notes on plan regarding verification of fire flow and proximity of hydrant or intent to install a fire sprinkler system. If a system will be installed, residential or quick response sprinklers shall be used. The sprinkler system may be connected to the domestic water supply, provided the required design density can be met. Be advised that Tucson Water will not allow a residential sprinkler system to be supplied by a 5/8" meter. A minimum of ¾" meter will be required by Tucson Water. Residential fire sprinkler system shall be installed in accordance with the 2018 IFC and NFPA 13D. |
| 11/08/2018 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T18CM07899 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. SITE PLAN: 1. Indicate the location of buildings, utility meters and gas, water, electric and sewer lines from property line to building, R106.1.1. Show the point of connection of proposed lines to the utility service for verifying correct sizes and necessary upgrades. FLOOR PLANS: 1. Identify the required side-hinged egress door, R311. Using door 2.7 will restrict the locking hardware options on door 4.5. 2. Clarify the door label for the garage door 2.1on schedule or 2.2 on plan sheet #2. 3. Indicate the direction of slope for the garage slab for drainage, R309.1. STRUCTURAL PLANS: 1. Show a cavalier porch beam size with appropriate load carrying capacity for the detail xxxx/Sd3.1 on the roof framing plan sheet S3.1, R301.1. Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 11/30/2018 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | FROM: David Rivera PDSD Zoning Review Section PROJECT: T18CM07899 Residential - Addition with DDO approval (1st Review) 641 N. Bentley Avenue TRANSMITTAL DATE: November 30, 2018 DUE DATE: November 29, 2018 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 01. COMMENT: The sheet index on the cover sheet shows that the site plan was included as sheet 1. There was not sheet one or a complete site plan in the building package. Revise the site plan on the cover sheet to include the site plan information in the attached sample document. 02. COMMENT: Zoning will approve only the plans that were stamped and signed by DDO plans review staff. The plans submitted for the building review do not include the DDO approval and signature. Once the plans are approved and stamped by the residential and fire plans reviewers and the 2 plan sets are re-stamped by the DDO plans review staff zoning will approve and sign off on the building plans. 03. COMMENT: Assure that the site plan information as noted in the sample site plan document is added to the cove sheet site plan. If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/17/2018 | QJONES1 | APPROVAL SHELF | Completed |
| 12/17/2018 | QJONES1 | OUT TO CUSTOMER | Completed |
| 12/17/2018 | QJONES1 | REJECT SHELF | Completed |