Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T18CM07772
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/17/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | T18CM07772 1) Provide flood vents for each enclosed horse stall. Each stall will require 1 square inch of venting per 1 square foot of floor area. Vents are to be located within 1' of grade. Suggest removing the lower 2x6 paneling on the front and rear of each stall. Update the profile and elevation views as needed to reflect the required flood openings. An elevation certificate completed by a registered land surveyor will be needed 2) Engineering can conduct an over the counter review once the above comment and any outstanding review comments are addressed. An elevation certificate along with a flood plain use permit will be issued upon the final review John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
| 10/24/2018 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/05/2018 | AVAUGHN1 | OUT TO CUSTOMER | Completed |