Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T18CM07762
Parcel: 134101320

Address:
8022 E HAYNE ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T18CM07762
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/29/2019 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed T18CM07762
8022 E HAYNE ST

PROVIDE COMPLETED PLAN SET WITH FLOOR PLAN (SCALE 1/4" = 1') SHOWING DOORS AND WINDOWS WITH SIZE FOR EGRESS. IDENFIFY EXISTING ADJACENT ROOMS AND NEW LAYOUT WITH DIMENSIONS.
PROVIDE A WALL SECTION WITH FOOTER DEPTH & FLOOR 6" ABOVE GRADE AND FASTENERS.
PROVIDE A ROOF FRAMING PLAN WITH RAFTER LAYOUT AND HEADER SIZES FOR NEW BEDROOM.
SHOW ELECTRICAL RECEPTACLES SPACED SO ALL WALL LOCATIONS ARE WITHIN 6 FEET. SHOW A SMOKE DETECTOR ON EACH SIDE OF ENTRANCE DOOR.
11/16/2018 ALEXANDRA HINES ZONING REVIEW Approved
11/16/2018 AHINES2 ENGINEERING REVIEW Passed
11/16/2018 AHINES2 NPPO REVIEW Passed