Permit Number: T18CM06851
Parcel: 125050280

Address:
2229 E 3RD ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T18CM06851
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/22/2019 AVAUGHN1 BUILDING-RESIDENTIAL REVIEW Needs Review
09/21/2018 MGAYOSS1 ZONING REVIEW Reqs Change FROM: María Gayosso, Lead Planner

PROJECT: T18CM06851, 2229 East 3rd Street, R-1

TRANSMITTAL: September 27, 2018

COMMENTS: The following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-1 zone (UDC 4.7.9). Single-family residential is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7.B.6, .9 & .10. The minimum required setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The applicant is proposing to construct a 13'0" tall attached garage in the rear of the property. Based on the garage's wall height of 13'0" the required perimeter yard setback to the north and east property lines is 8'-7". The applicant is proposing a setback of 2'0" to the north and 6'0" to the east.

The project also includes a new attached porch connecting the existing studio to the main dwelling, at a height of 9'4". The required setback from the west property line is 6"2", but applicant is proposing a setback of 33" (2.75').

A DDO approval is required for the proposed reduced setbacks from the north, east and west property lines for the new attached garage and the new attached porch, prior to zoning approval.
09/21/2018 MGAYOSS1 ZONING REVIEW Reqs Change FROM: Kelly Lee
Lead Planner

PROJECT:
T18CM06851
2229 E 3rd Street
New attached covered porch & new attached rear garage

TRANSMITTAL: September 21, 2018
COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The building height of the new attached covered porch facing the west property line is 9 feet 4 inches. The required setback is 6 feet 2 inches and the proposed setback is 3 feet.


The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The building height of the new attached garage is 13 feet. The required setback from the north and east property lines is 8 feet 8 inches and the proposed setback is 2 feet to the north property line and 6 feet to the east property line.