Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T18CM06730
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/15/2018 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 10/15/2018 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | Previous two comments not addressed: If mechanical system is being altered or replaced, a mechanical plan will be required. Please verify. (exhaust fan for new restroom?) |
| 10/15/2018 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | The restrooms will require exhaust fans per the Mechanical review. Please show the exhaust fan locations and power supply,controls. NEC 408.4 |
| 10/15/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. The ASSE 1070-listed mixing valve is required to be installed with the new lavatory. Watts does not endorse the use of the LFMMV mixing valve at the hot water source. [Initial comment: The ASSE 1070 thermostatic mixing valve is for point-of-use applications. It is required at the lavatory.] 2. A Watts model LF7R dual check valve is not listed to ASSE 1022 (see the note for the ice maker). [Initial comment: Specify the backflow prevention devices required for the coffee maker and the ice machine (e.g. an ASSE 1022 dual check valve is required for the coffee maker)]. 3. The fixture unit schedule, when used to determine the water demand seen by a water meter, needs to include all of the plumbing fixtures served by the water meter. 4. The registrant's seal must be signed and dated. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/19/2018 | QJONES1 | APPROVAL SHELF | Completed |
| 10/19/2018 | QJONES1 | OUT TO CUSTOMER | Completed |
| 10/19/2018 | QJONES1 | REJECT SHELF | Completed |