Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T18CM06730
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/14/2018 | GPERU1 | BUILDING-COMMERCIAL | REVIEW | Reqs Change | The comments from the structural/architect plan review have not been corrected on the plans. All corrections need to be placed on the architecutal plans and clouded for identification. |
09/14/2018 | ROBERT SHERRY | WATER | REVIEW | Completed | |
09/14/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Coordinate the water heater detail with the water riser diagram (e.g. water heater detail does not show recirculation piping. 2. The ASSE 1070 thermostatic mixing valve is for point-of-use applications. It is required at the lavatory. 3. Specify the backflow prevention devices required for the coffee maker and the ice machine (e.g. an ASSE 1022 dual check valve is required for the coffee maker). |
09/14/2018 | GPERU1 | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | The electrical plan review comments have not been addressed. Please provide lighting calculations or Com Check compliance for interior lighing per the previous electrical comment. |
09/14/2018 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | Previous comment not addressed: If mechanical system is being altered or replaced, a mechanical plan will be required. Please verify. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
09/27/2018 | QJONES1 | APPROVAL SHELF | Completed |
09/27/2018 | QJONES1 | OUT TO CUSTOMER | Completed |
09/27/2018 | QJONES1 | REJECT SHELF | Completed |